MYLUNG EARLY RESULTS

MyLung app was tested by 10 COPD patients and experts.  Using SUS scoring, it received a score of 83.5, far above the 68 considered good in usability.

In a random control experiment, in which 10 patients in control group used traditional methods and 11 patients used MyLung system, the following significant results were seen.

MeasureMean for Intervention GroupMean for Control GroupMean differenceLevene's Test (F)Levene's Test (Sig)tSig. (2-tailed)
Awareness level3.283.330.0455.860.00260.1950.84ns
Self-efficacy3.1140.883.60.0731.570.131ns
Perceived-severity3.032.520.52.720.111.820.084ns
Behavioral-intention2.913.10.1911.110.30.390.701ns
MeasureControl (n=10)Intervention (n=11)
Mean Before Mean AfterMean of DifferenceMean BeforeMean AfterMean of Difference
Awareness level3.333.310.0163.284.561.27
(P=.95ns)(***P<.001)
Self-efficacy 43.660.333.115.562.44
(P=.38ns)(**P<.014)
Perceived-severity 2.522.950.433.033.280.25
(P=.131ns)(P=.601ns)
Behavioral-intention 3.13.60.52.914.551.63
(P=.343ns)(**P<.009)

Note

*** p < .001; ** p < .01; * p < .05; ns = not significant; N = 11 for the intervention group & N = 10 for the control group